The new, smaller cylindrical shape of Wireless Vacuum Gauge, its no-slip grip, and the addition of reversible angled coupler — mean MG44 is easy to manipulate and install in the toughest spots..
Range and Units 50 to 25000 microns of mercury, 6 to 3333 Pascals, 0.06 to 33.33 mBar, 50 to 25000 mTorr, 0.05 to 25 Torr.
Best Resolution of mercury, Pascal, 0.001 mBar, mTorr, 0.001 Torr.
Anything outside of that range will show the 4 dashes -. The bar graph will show wider range from deep vacuum up to atmosphere.
Anything outside of that range will show the 4 dashes -. The bar graph will show wider range from deep vacuum up to atmosphere...
The inside the system is still boiling off and is no longer being taken out or compensated for by the vacuum pump. The system will have to come to equilibrium stabilizing...
Connect MG44 to empty tank and pull down to 500 microns and isolate the pump from tank and microns should rise not immediately fast rise...
Evacuation takes time. You pulling in larger volume compared to just vacuum pump. Check that there are no leaks in your hoses, change the oil of the vacuum pump, and perform evac if there is indication of lot of in the system.
add MG44 to the in the app...
Microns being inaccurate is sign of oil holding moisture either inside the block of the manifold, In the hoses or the in your vacuum pump needs to be changed..